Sign In | Join Free | My burrillandco.com
Home > Box Type Substation >

10kV Box Type Electric Distribution Substation High Voltage IP56 Protection Customized

Shenzhen Dong Sheng Yuan Electrical Equipment Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 10kV Box Type Electric Distribution Substation High Voltage IP56 Protection Customized from wholesalers
     
    Buy cheap 10kV Box Type Electric Distribution Substation High Voltage IP56 Protection Customized from wholesalers
    • Buy cheap 10kV Box Type Electric Distribution Substation High Voltage IP56 Protection Customized from wholesalers
    • Buy cheap 10kV Box Type Electric Distribution Substation High Voltage IP56 Protection Customized from wholesalers
    • Buy cheap 10kV Box Type Electric Distribution Substation High Voltage IP56 Protection Customized from wholesalers
    • Buy cheap 10kV Box Type Electric Distribution Substation High Voltage IP56 Protection Customized from wholesalers

    10kV Box Type Electric Distribution Substation High Voltage IP56 Protection Customized

    Ask Lasest Price
    Brand Name : Dong Sheng Yuan
    Model Number : 10kV Southern Power Grid Primary And Secondary Integrated Equipment (ring Network Box)
    Delivery Time : T+30
    Payment Terms : TT
    • Product Details
    • Company Profile

    10kV Box Type Electric Distribution Substation High Voltage IP56 Protection Customized

    Basic Info.

    Model NO.
    American substation

    Form
    Partly-welded Type
    Operation Voltage
    High Voltage
    Size
    3 Uint
    Application Range
    Power Plants
    Shell Material
    Stainless Steel
    Shell Protection Grade
    IP56
    Brand
    DSY
    Transport Package
    Customized
    Specification
    customized
    Trademark
    DSY
    Origin
    China, Zhuhai
    Production Capacity
    3000

    Packaging & Delivery

    Package Size
    1750.00cm * 1600.00cm * 2200.00cm
    Package Gross Weight
    460.000kg

    Product Description

    Transformer technical parameters table
    Product Description

    Main technical parameter

    Preassembled substation technical parameter table

    Serial numberNameUnitTechnical specification
    1rated voltageKV10/0.4(high voltage/low voltage)
    2maximum working voltageKV12(high-pressure side)
    3rated frequencyHZ50
    4rated capacityKVA50-1600
    51-minute power frequency withstand voltageKV35
    6lightning impulse voltageKV75
    7type of cooling
    Oil immersed in self-cooling
    8High voltage backup fuse breaking currentKA50
    9Breaking the current of the plug-in fuseKA2.5
    10environment temperatureºC-35~+40
    11Coil allowable temperature riseºC65
    12No load voltage regulation
    ±5%or±2x2.5%
    13noise gradedb50
    14level of protection
    IP43


    Transformer technical parameters table

    Selection of new S9 series transformer body, low loss, good overload capacity, strong short-circuit resistance, all fasteners are anti-loose treatment, no lifting core; S10 series and S11 series transformers with better performance are also available.
    Capacity kvaVoltageno-load currentopen circuit lossesimpedance voltageload loss
    high voltagelow voltageS9S10S11S9S10S114.0S9S10S11
    5010±5%
    ±2x2.5%
    0.42.01.90.750.170.150.120.870.830.87
    631.91.80.70.20.180.141.040.991.04
    801.91.70.70.250.220.1751.251.21.25
    1001.81.550.650.290.260.21.51.421.5
    1251.71.450.650.340.30.2351.81.721.8
    1601.61.30.60.40.360.272.22.122.2
    2001.51.20.550.480.430.332.62.52.6
    2501.41.10.50.560.50.393.052.93.05
    3151.41.00.450.670.290.4653.653.453.65
    4001.31.00.40.80.710.564.34.154.3
    5001.21.00.40.960.850.675.154.825.15
    6301.10.80.41.21.60.814.56.25.866.2
    8001.00.70.351.41.230.987.57.27.5
    10001.00.60.31.71.51.1510.39.810.3
    12500.90.60.271.951.721.3612.012.212.0

    main technical parameters

    Load switch technical parameter table

    The load switch is an oil-immersed, three-phase linkage switch with, spring operating mechanism. It can be operated with load division and brake, and its division and speed have nothing to do with the size of the operating force. There are two stations, four stations T-type, four stations V-type, and so on.

    Serial numberNameUnitFour-station loop load switchTwo-station load switch
    1rated voltageA630315
    2Rated short-circuit closing currentKA31.531.5
    3rated short-time currentKA12.512.5
    4Rated short endurance timeS22
    5mechanical lifeNext20002000
    6Lightning impulse withstand voltage peak full wavePhase to phaseKV7575
    7isolating fracture
    8585
    81min power frequency withstand voltagePhase to phaseKV4242
    9isolating fracture
    4848
    10Rated peak withstand currentKA31.531.5

    Fuse technical parameters(The company oil oil-immersed fuse selection configuration recommendation table)


    Serial numberThree-phase transformer capacity(KVA)XRNT rated current(A)PRNT1 Overload protection rated current(A)
    130106
    250168
    3801610
    41002015
    51252515
    616031.525
    72004025
    82505040
    93156340
    104006340
    115008050
    1263010050/65
    1380012565
    141250160100
    151600200140


    Quality 10kV Box Type Electric Distribution Substation High Voltage IP56 Protection Customized for sale